전자 / 통신 관련 계측기
  계측기기 및 판넬메타
  이화학 /산소 /수질 / 온습도 / 가스 /기록계(Recorder)/도막두께/조도계/풍속계/열화상
  교육 기자재 / 로봇 실습
  광학기기 - 현미경
  자동전압조정기 (AVR) 무정전전원장치 (UPS) 주파수변환기 (CVCF)
  슬라이닥스 / 승압,다운 트랜스
  측정공구/일반공구/납땜관련
  초음파 세정기
  전자부품
HOME > 제품소개 > 전자 / 통신 관련 계측기 > OSCILLOSCOPE
전자 / 통신 관련 계측기 > OSCILLOSCOPE
 
제품명: 200MHz 2[4}-Channel Digital Oscilloscope HMO2022 _2024
모델명 : HMO-2022 HMO-2024
제조회사 : HAMEG

200 MHz 2[4] Channel Digital Oscilloscope     HMO2022 [HMO2024]

150 MHz 2[4] Channel Digital Oscilloscope     HMO1522 [HMO1524]

 

 

 2 GSa/s Real Time, Low Noise Flash A/D Converter  (Reference Class)
 2 MPts Memory, Memory oom up to 50,000:1
 MSO (Mixed Signal Opt. HO3508) with 8 Logic Channels
◎ 
Serial Bus Trigger and Hardware accelerated Decode,   I2C, SPI, UART/RS-232
    (Opt. HOO10, HOO11)
 8 User definable Markers for easy Navigation
 Pass/Fail Test based on Masks
 Vertical Sensitivity 1 mV/div., Offset Control ±0.2...±20 V
 12 div. x-Axis Display Range, 20 div. y-Axis Display Range  (VirtualScreen)
 Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event
 Component Tester, 6 Digit Counter, Automeasurement, Formula Editor,
    Ratiocursor,  FFT for Spectral Analysis
 Crisp 16.5 cm (6.5”) TFT VGA Display, DVI Output
 Lowest Noise Fan
3 x USB for Mass Storage, Printer and Remote Control
   optional IEEE-488 (GPIB) or Ethernet/USB


        Display                                                                                    

Display  

16.5 cm (6.5”) VGA Color TFT

Resolution

640 x 480 Pixel

Backlight

LED 400 cd/m2

Display area for curves:

     without menu

400 x 600 Pixel (8 x 12 div.)

      with menu

400 x 500 Pixel (8 x 10 div.)

Color depth

256 colors

Intensity steps per trace 

0…31

       Vertical System 

Channels:

 

       DSO mode

CH 1, CH 2 [CH 1...CH 4]

       MSO mode

CH 1, CH 2, LCH 0…7 (logic channels)
[CH 1, CH 2, LCH 0…7, CH4] with Option HO3508

Auxiliary input

Frontside [Rear side]

       Function

Ext. Trigger

       Impedance  

1 MΩ || 14 pF ±2 pF

       Coupling

DC, AC

      Max. input voltage

100 V (DC + peak AC)

XYZ-mode 

All analog channels on individual choice

Invert 

CH 1, CH 2 [CH 1...CH 4]

Y-bandwidth (-3 dB)       (HMO202x)

200 MHz (5 mV…5 V)/div, 100 MHz (1 mV, 2 mV)/div

Y-bandwidth (-3 dB)       (HMO152x)

150 MHz (5 mV…5 V)/div, 100 MHz (1 mV, 2 mV)/div

Lower AC bandwidth

2 Hz

Bandwidth limiter (switchable) 

approx. 20 MHz

Rise time (calculated) (HMO202x) 

<1.75 ns

Rise time (calculated) (HMO152x)

<2.4 ns

DC gain accuracy

2 %

Input sensitivity

12 calibrated steps

       CH 1, CH 2 [CH 1...CH 4]

1 mV/div.…5 V/div. (1–2–5 Sequence)

       Variable

Between calibrated steps

Inputs CH 1, CH 2 [CH 1…CH 4]

       Impedance 

MΩ || 14 pF ±2 pF (50 Ω switchable)

       Coupling

DC, AC, GND

       Max. input voltage

200 V (DC + peak AC), 50 Ω <5 Vrms

Measuring circuits

Measuring Category I (CAT I), UL 61010B-1

Position range

±10 Divs

Offset control:

       1 mV, 2 mV

±0,2 V - 10 div. x Sensitivity

       5…50 mV

±1 V - 10 div. x Sensitivity

       100 mV 

±2,5 V - 10 div. x Sensitivity

       200 mV…2 V

±40 V - 10 div. x Sensitivity

       5 V  

±100 V - 10 div. x Sensitivity

Logic channels  

With Option HO3508

       Select. switching

       thresholds 

TTL, CMOS, ECL, User -2…+8 V

Impedance

100 kΩ || <4 pF

Coupling

DC

Max. input voltage

40 V (DC + peak AC)

              Triggering

Analog channels:

Automatic

Linking of peakdetection and triggerlevel

       Min. signal height 

0.8 div.; 0.5 div. typ. (1.5 Div at 2 mV/Div)

       Frequency range           (HMO202x) 

5 Hz…250 MHz (5 Hz…120 MHz at 2 mV/Div)

     Frequency range           (HMO152x)

5 Hz…200 MHz (5 Hz…120 MHz at 2 mV/Div)

      Level control range From

peak- to peak+

Normal (without peak):

       Min. signal height

0.8 div.; 0.5 div. typ. (1.5 Div at 2 mV/Div)

      Frequency range           (HMO202x)

0…250 MHz (0 Hz…120 MHz at 2 mV/Div)

      Frequency range           (HMO152x) 

0…200 MHz (0 Hz…120 MHz at 2 mV/Div)

      Level control range

-10...+10 div from center of the screen

Operating modes 

Slope/Video/Logic/Pulses/Busses (optional)

Slope 

Rising, falling, both

      Sources

CH 1, CH 2, Line, Ext., LCH 0…7
[CH 1...CH 4, Line, Ext., LCH 0…7]

      Coupling (Analog Channel)

AC (HMO202x): 5 Hz...250 MHz
AC (HMO152x): 5 Hz...200 MHz
DC (HMO202x): 0...250 MHz
DC (HMO152x): 0...200 MHz
HF (HMO202x): 30 kHz...250 MHz
HF (HMO152x): 30 kHz...200 MHz
LF: 0...5 kHz
Noise rejection: switchable 

Video

       Standards

PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV
720p, HDTV 1080i, HDTV 1080p

       Fields

Field 1, field 2, both

       Line

All, selectable line number

       Sync. Impulse

Positive, negative

       Sources

CH 1, CH 2, Ext. [CH 1...CH 4]

Logic 

       Sources

LCH 0…7

       State 

LCH 0…7 X, H, L

Pulses

Positive, negative

       Modes

equal, unequal, less than, greater than,                         within/without a range

       Range

min. 32 ns, max. 10 s, resolution min. 8 ns

Sources

CH 1, CH 2, Ext. [CH 1...CH 4]

Indicator for trigger action

LED

Ext. Trigger via

Auxiliary input 0.3 V…10 Vpp

2nd Trigger:

       Slope

Rising, falling, both

       Min. signal height 

0.8 div.; 0.5 div. typ. (1.5 Div at ^ 2 mV/Div)

       Frequency range          (HMO202x)

0…250 MHz (1.5 div at ≤2 mV/div)

       Frequency range          (HMO152x)

0…200 MHz (1.5 div at ≤2 mV/div)

       Level control range

-10...+10 div.

       Operating modes:

       after time

32 ns…10 s

       after incidence

 

Busses (Opt. HOO10) 

I2C/SPI/UART/RS-232

       Sources

CH 1, CH 2, Ext., LCH 0…7
[CH 1...CH 4, Ext., LCH 0…7]

Busses (Opt. HOO11)

2C/SPI/UART/RS-232

       Sources

CH 1, CH 2, Ext. (for Chip Select at SPI)                                    [CH 1...CH 4, Ext.] (for Chip Select at SPI)

       Format

hexadecimal, binary

       I²C

Trigger on Start, Stop, Restart, NACK, Adress (7
or 10 Bit), Data, Adress and Data, up to 5 Mb/s

       SPI

up to 32 Bit Data, Chip select (CS) pos.
or neg., without CS, up to 12.5 Mb/s

       UART/RS-232

up to 8 Bit Data, up to 31 Mb/s

                Horizontal System

Domain representation

Time, Frequency (FFT), Voltage (XY)

Representation Time Base

Main-window, main- and zoom-window

Memory Zoom 

Up to 50,000:1

Accuracy

50 ppm

Time Base 

2 ns/div.…50 s/div

      Roll Mode

50 ms/div.…50 s/div.

                 Digital Storage             

Sampling rate (real time)

2 x 1 GSa/s, 1 x 2 GSa/s [4 x 1 GSa/s, 2 x 2 GSa/s]

Logic channels

8 x 1 GSa/s

Memory

2 x 1 MPts, 1 x 2 MPts [4 x 1 MPts, 2 x 2 MPts]

Operation modes 

Refresh, Average, Envelope, Peak-Detect Roll:
free run/triggered, Filter, HiRes

Resolution (vertical)

8 Bit, (HiRes up to 10 Bit)

Resolution (horizontal)

40 ps

Interpolation

Sinx/x, linear, Sample-hold

Persistence

Off, 50 ms...∞

Delay pretrigger

0...8 Million x (1/samplerate)

posttrigger

0...2 Million x (1/samplerate)

Display refresh rate

Up to 2000 waveforms/s

Display 

Dots, vectors, „persistence“

Reference memories

typ. 10 Traces

              Operation/Measuring/Interfaces 

Operation

Menu-driven (multilingual), Autoset, help
functions (multilingual)

Save/Recall memories

typ. 10 complete instrument parameter settings

Frequency counter:

       0.5 Hz...250 MHz          (HMO202x)

6 Digit resolution

       0.5 Hz...200 MHz          (HMO152x)

6 Digit resolution

       Accuracy

50 ppm

Auto measurements

Amplitude, standard deviation, Vpp, Vp+, Vp-, Vrms,
Vavg, Vtop, Vbase, frequency, period, pulse count,
twidth+, twidth-, tdutycycle+, tdutycycle, trise, tfall,
pos.edge, count, neg. edge count, pos. pulse count,
neg. pulse count, trigger frequency, trigger period,
phase, delay

Cursor measurements

ΔV, Δt, 1/Δt (f), V to Gnd, Vt related to Trigger point,
ratio X and Y, pulse count, peak to peak, peak+,
peak-, mean value, RMS value, standard deviation
Interface: Dual-Interface USB type B/RS-232 (HO720),
2x USB type A (front- and rear side each 1x) max.
100 mA, DVI-D for ext. Monitor

Optional

IEEE-488 (HO740), Ethernet/USB (HO730)

                 Display functions

Marker

up to 8 user definable marker for easy  navigation

VirtualScreen

virtual Display with 20 div. vertical for all Math-,
Logic-, Bus- and Reference Signals

Busdisplay

up to 2 busses, user definable, parallel or serial
busses (option), decode of the bus value in ASCII,
binary, decimal or hexadecimal, up to 4 lines

Parallel 

logic channels can also be used as source for
bus definition

I²C   
(Opt. HOO10, HOO11)

color coded Read-, Write Adress, Data, Start,
Stop, acknowledge, missing acknowledge,
Errors and Trigger condition

SPI
(Opt. HOO10, HOO11)

color coded Data, Start, Stop, Errors and Trigger
condition

UART/RS-232
(Opt. HOO10, HOO11) 

color coded Data, Start, Stop, Errors and Trigger
condition

                       Mathematic functions

Number of formula sets

5 formula sets with up to 5 formulas each

Sources

All channels and math. memories

Targets

Math. memories

Functions

ADD, SUB, 1/X, ABS, MUL, DIV, SQ, POS, NEG,
INV, INTG, DIFF, SQR, MIN, MAX, LOG, LN, Low-,
High-pass filter

Display

Up to 4 math. memories with label

                      Pass/Fail functions

Sources

Analog channels

Type of test

Mask around a signal, userdefined tolerance

Functions

Stop, Beep, screen shot (screen print-out) and/or
output to printer for pass or fail, event counting
up to 4 billion, including the number and the
percentage of pass and fail events

                      General Information

Component tester

Test voltage

10 VP (open) typ.

Test current

10 mAP (short) typ.

Test frequency

50 Hz / 200 Hz typ.

Reference Potential

Ground (safety earth)

Probe ADJ Output

1 kHz/1 MHz square wave signal ~1Vpp (ta <4 ns)

Bus Signal Source

SPI, I2C, UART, Parallel (4 Bit)

Internal RTC (Realtime clock)

Date and time for stored data

Line voltage

100…240 V, 50...60 Hz, CAT II

Power consumption

Max. 45 W, typ. 25 W [max. 55 W, typ. 35 W]

Protective system

Safety class I (EN61010-1)

Operating temperature

+5...+40 °C

Storage temperature

-20...+70 °C

Rel. humidity

5...80 % (non condensing)

Dimensions (W x H x D)

285 x 175 x 140 mm

Weight

<2.5kg

Accessories supplied: Line cord, Operating manual, 2 [4] Probes, 10:1 with
attenuation    ID (HZO10), CD
Recommended accessories you can find at www.hameg.com/embedded

 

본 카다록은 홈페이지 상단의 질문과 답변 클릭한 후 왼쪽 자료실에서 PDF 파일을 다운 받으십시요.